Monday, April 15, 2013

ECT Display Driver – Installation for AP2 Module

The ECT Display Driver is a small module with a removable wire harness that mounts behind the driver’s foot well cover. All wiring connections are near the ECM and only 4 wires are needed for basic operation:
• +5v power from the ECM (T-tap)
• Ground – available at ECM mounting bolt
• ECT sensor wire (T-tap at ECM)
• Dash temperature gauge wire (must cut at ECM)


If you want to use the optional Alarm Output feature 3 more wires are needed:
• Ground (must be run separate from the module’s power ground)
• Module output (negative) to your alarm device (sounder or indicator light, not included)
• +12v ignition or accessory power wired directly to your alarm device

Installation Details: refer to the photos and wiring diagram at the end of this manual
1. Remove the driver’s side doorsill trim and the driver’s foot well trim. (if you don’t know how to do this you probably shouldn’t be doing this modification)
2. Locate the connectors and wires you will be using, see photos at the end of this manual.
a. Temperature gauge wire (Yellow/Green) – Easily seen at the top left of connector A on the ECM.
b. Power wire for +5v (Yellow/Blue) – This is on the rear-most row of wires on connector C, in the ‘middle’ section of the connector. You will have to remove connector C from the ECM to locate this wire
c. ECT Sensor wire (Red/White) – This is also on the rear-most row of wires on connector C, in the ‘middle’ section of the connector.
3. Attach crimp connectors to the ECM wires as detailed below.
a. Using a pair of pliers, clamp one of the red T-taps around the Yellow/Blue wire in connector C, making sure the wire goes into the metal slot of the T-tap. If you have strong fingers you can squeeze the T-tap on the wire to hold it temporarily, then use the pliers to clamp it shut. Or, you can position the T-tap in the pliers’ jaw, then clamp it on the wire.
b. Crimp another T-tap around the Red/White wire in connector C.
c. Now cut the Yellow/Green wire a few inches away from the ECM and strip about ž” of insulation from each end.
d. Using a crimp tool, crimp a female spade connector on the end of the Yellow/Green wire that comes from the ECM.
e. Next crimp a male spade connector on the other end of the Yellow/Green wire (the end going into the wire bundle).
f. Note that the ends of the Yellow/Green wire have opposite connectors. If you ever have to remove the ECT Module you simply plug these connectors together and the temperature gauge will work like normal.